Spectra Tech employes sophisticated equipment and software to measure and document the Day-Night Average Sound Level (Ldn) as well as the associated Daytime Average Sound Level (Lday), Evening Average Sound Level (Levening), Nighttime Average Sound Level (Lnight). We can also provide assistance in designing solutions to reduce excessive noise, either at the “source” or “receiving” location.
- Testing can be conducted in accordance with ASTM E1014-08 Standard Guide for Measurement of Outdoor A-Weighted Sound Levels, ASTM E-1503-06 Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System, or ISO 1996 Acoustics — Description, measurement and assessment of environmental noise — Part 1: Basic quantities and assessment procedures
- The Day-Night Average Sound Level (Ldn) are derived from formulae in accordance with the HUD standard.
- We employ self-contained weatherproof systems that can operate unattended on battery for up to one week, with onboard memory to measure noise levels continuously in order to derive the Day-Night Average Sound Level (Ldn) and associated results.
- Our systems can simultaneously log the noise spectrum in all 1-octave or 1/3-octave bands, providing a basis for design of noise mitigation measures.
- To further help in identifying the source(s) of excessive noise, our systems can record actual audio of noise that exceeds preset thresholds
Spectra Tech Ltd,Example – Field Test Plot- Ldn + Leq + Spectrum for a 24 hour period - Plot / Print Test Results: We can provide documentation of test results by plotting / printing the test values on paper, and / or provide the results in PDF format.
LINKS TO RELATED REFERENCE INFORMATION
- Noise, Vibration, Control, new hospital, Mercy Hospital West, Cincinnati, OH, Spectra Tech Ltd, Consultant
- Emergency Generator, Noise, Vibration, Control, Challenges, Spectra Tech Ltd, Consultant
- Community Response to http://”http://spectratechltd.com/projects/spectratechltd/wp-content/uploads/2018/05/mercy-hospital-west-project-profile.pdfNoise – based on Ldn, Spectra Tech Ltd, Consultant
- Testing to Identify and Rate Community Environmental Noise Sources
- 24 CFR Part 51 – Environmental Criteria and Standards (HUD) – links to HUD website)
- Environmental Noise, B&K Technical Publication: Spectra Tech Ltd, Consultant
- Environmenhttp://jayanwerdesign.com/projects/spectratechltd/wp-content/uploads/2018/05/testing-to-identify-and-rate-community-environmental-noise-sources.pdftal Noise Measurement, B&K Technical Publication: Spectra Tech Ltd, Consultant
- Community Response to Noise – % Annoyed by Ldn, Spectra Tech Ltd, Consultant
- EPA Data – % of People Disturbed by Various Ldn Noise Levels, Spectra Tech Ltd, Consultant
- EPA Recommended Community Noise Level Values to Protect Public Health & Welfare, Spectra Tech Ltd, Consultant
- EPA Recommended Correction Factors for Measured Ldn, Spectra Tech Ltd, Consultant
- World Health Organization Recommendations for Noise Levels at Residences, Schools, & Hospitals, Spectra Tech Ltd, Consultant
- Noise Levels of Common Exterior Sources, Spectra Tech Ltd, Consultant